Venstar Skyport Communications Guide d'installation Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
6
MAKING 4 WIRES WORK when 5 are required
(without the optional Add-A-Wire accessory)
• If you have an all-electric heat system with air conditioning, this
method is not an option. You must either pull new wire or use the
optional Add-A-Wire accessory (ACC-0410).
• If you have a single stage fossil fuel heater with air conditioning,
and you would like install the Venstar ColorTouch using only 4 wires,
follow the directions below. You will need a screwdriver along with a
3” or 4” long piece of thermostat wire to use as a jumper.
1. Makesurethepowerisoasstep1onpage4instructsyou.
2. Followstep4onpage9“LabelandDisconnectWires”atthe
thermostat.Pleasenotethecolorandthecorrespondingwire
designatorwitheachcolor.AnexampleistheRwireisredandthe
Wwireiswhiteandsoon.Youwillneedthisforthenextstepat
theHVACequipment.
3. Attheequipmentendofthethermostatwires,locatethe
terminals that the wires are attached to.
A. Removethe“Gwire”fromtheterminalmarkedG.
B. Placethe“Gwire”onterminalC.
C. PlaceoneendofthejumperonterminalG.
D. PlacetheotherendofthejumperonterminalY.
 Pleasenotethattherewillbemorethan1wireonterminalY.
4. Connect the wires to the terminals on the ColorTouch backplate
takingcaretomakesurethateachwirefromtheHVACequipment
is connected to the same terminal designation on the ColorTouch
backplate.Forexample:the“Cwire”fromtheHVACequipment
shouldbeconnectedtothe“C”terminalofthethermostat.The
“R”wireontheequipmentterminalshouldbeconnectedtothe
“R”terminalontheColorTouchbackplate,andsoon.
Vue de la page 7